Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Shoulder Procedure Volumes in Orthopaedic Residency: Long-Term Disparities and a Case for Arthroplasty Minimums.

Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews·2026
Same author

Torque provides a more comprehensive assessment of reverse total shoulder arthroplasty lateralization than moment arms or muscle forces.

Journal of biomechanics·2026
Same author

Graft Height and Labral Integrity as Key Determinants of Suction Seal Restoration in Hip Labral Augmentation: Findings From an Ovine Model.

Orthopaedic journal of sports medicine·2026
Same author

Rat Model of Gluteus Medius Tendon Tear: Biomechanical and Histological Effects of Autologous Fascia Lata Augmentation.

The American journal of sports medicine·2026
Same author

Relationship Between Cam Lesion Size, Its Excision, and Hip Osteoarthritis Progression: A Contralateral-Controlled Study Using Joint Space Width After Unilateral Hip Arthroscopy.

Orthopaedic journal of sports medicine·2026
Same author

Prior cervical spine fusion impairs early clinical outcomes following total shoulder arthroplasty and may be associated with increased fusion burden: a matched cohort analysis.

JSES international·2026

Related Experiment Video

Updated: Jul 17, 2025

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
06:36

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects

Published on: December 10, 2021

2.9K

All-Endoscopic Modified Krackow Suture for Proximal Hamstring Repair.

Christopher M Brusalis1, Thomas W Fenn1, Jordan H Larson1

  • 1Department of Sports Medicine and Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, U.S.A.

Arthroscopy Techniques
|September 1, 2023
PubMed
Summary

This study introduces an all-endoscopic running locking stitch for proximal hamstring repair, enhancing suture security at the tendon interface. This technique aims to improve outcomes for active individuals with hamstring injuries.

More Related Videos

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
10:32

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons

Published on: June 3, 2020

5.7K
Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy
03:24

Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy

Published on: January 26, 2024

854

Related Experiment Videos

Last Updated: Jul 17, 2025

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
06:36

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects

Published on: December 10, 2021

2.9K
Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
10:32

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons

Published on: June 3, 2020

5.7K
Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy
03:24

Author Spotlight: Development and Application of a Novel Suture Technique for Annular Fibrosus Repair in Percutaneous Transforaminal Endoscopic Discectomy

Published on: January 26, 2024

854

Area of Science:

  • Orthopedic Surgery
  • Sports Medicine
  • Biomedical Engineering

Background:

  • Proximal hamstring injuries significantly impact active individuals.
  • Open surgical repair is traditional, while endoscopic repair offers potential benefits like fewer complications.
  • Current endoscopic techniques may have reduced suture-tendon interface security compared to open methods.

Purpose of the Study:

  • To present a novel all-endoscopic technique for proximal hamstring repair.
  • To enhance suture purchase and security at the suture-tendon interface during endoscopic repair.
  • To address a theorized disadvantage of existing endoscopic proximal hamstring repair methods.

Main Methods:

  • Development and description of an all-endoscopic running locking stitch technique.
  • Application of the technique during proximal hamstring repair procedures.
  • Comparison of suture security with traditional open and existing endoscopic methods (implied).

Main Results:

  • The presented technique increases suture purchase at the suture-tendon interface.
  • This method allows for an all-endoscopic running, locking stitch during proximal hamstring repair.
  • Potentially improves security compared to other endoscopic approaches.

Conclusions:

  • The all-endoscopic running locking stitch is a viable technique for proximal hamstring repair.
  • This method enhances suture security, potentially overcoming limitations of current endoscopic approaches.
  • Offers a promising advancement for restoring function in active individuals with hamstring injuries.