[Rythmology activity in France and consequences of new thresholds approvals]
Walid Amara1, Camille Renault2, Pierre Socie3
1CHI Le Raincy Montfermeil, France.
Background:
Interventional rhythmology activity (electrophysiology and pacing) has progressed in France during the last decade. The objective of this article is to assess the distribution of this activity depending on the type of centre (public, university or non-university, private). As the French government issued a new regulation regarding rhythmology activity in 2022, the impact of this regulation on activity distribution has been evaluated.
Methodology:
All French data activity can be evaluated after accessing to a national database called PMSI [Programme de Médicalisation des Systèmes d'Information]. Based on data collected in year 2021, the level of activity of the different centres, and the impact of the new criteria of the French regulation regarding rhythmology activity have been analysed.
Results:
About 200,000 arrhythmias interventions have been done in France in 2021 in 382 centres. According to the new criteria of the French regulation, 66% responded to level A (diagnostic electrophysiology, single- and dual-chamber pacing), 68% for level B (A+ right atrial ablation, implantable automatic defibrillator, cardiac resynchronisation therapy) and 70% for level C (B + left atrial and ventricular ablation). 1/4 of the centres do not meet criteria for level A activity, and 1/5 of them for levels B and C CONCLUSIONS: This work showed that immediat and systematic application of new threshold could be threatening for 1/4 of A center and 1/5 of B or C center. The priority will be to reinforce existing centres before allowing new centres to perform arrhythmias management activity in France.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Beats
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...