On catching the preparatory phase of damaging earthquakes: an example from central Italy

Matteo Picozzi1, Antonio G Iaccarino2, Daniele Spallarossa3

  • 1University of Naples Federico II, Naples, Italy. matteo.picozzi@unina.it.

Scientific Reports
|September 1, 2023
PubMed

Related Concept Videos

Microcracking in Concrete01:20

Microcracking in Concrete

Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
149
Prestressed Concrete01:20

Prestressed Concrete

Prestressed concrete is a construction technique designed to enhance the strength and durability of concrete structures. This method involves the application of a pre-set tension to high-strength steel strands used as reinforcement before the concrete is subjected to its working loads. The primary aim of prestressing is to place the concrete in a state of compression, in order to counteract the tensile forces it will experience in service. This pre-compression helps prevent crack formation in...
169
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
106
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
218
Bending Moment Diagram01:30

Bending Moment Diagram

A bending moment diagram is a graphical representation of the bending moments experienced by a beam under load along the beam length. It is an essential tool for engineers and designers to analyze structures and ensure they can withstand applied forces. The steps to create the bending moment diagram for a beam are listed below.
Determine reactive forces and couple moments: Calculate all the reactive forces and couple moments acting on the beam. In certain cases, when the beam is inclined at an...
1.2K
Mortar Joint Deterioration in Masonry01:13

Mortar Joint Deterioration in Masonry

Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
137