Enabling cuboid-based fisher ratio analysis using total-transfer comprehensive three-dimensional gas chromatography
Sonia Schöneich1, Caitlin N Cain1, Paige E Sudol1
1Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA.
Abstract:
Comprehensive three-dimensional (3D) gas chromatography with time-of-flight mass spectrometry (GC3-TOFMS) is a promising instrumental platform for the separation of volatiles and semi-volatiles due to its increased peak capacity and selectivity relative to comprehensive two-dimensional gas chromatography with TOFMS (GC×GC-TOFMS). Given the recent advances in GC3-TOFMS instrumentation, new data analysis methods are now required to analyze its complex data structure efficiently and effectively. This report highlights the development of a cuboid-based Fisher ratio (F-ratio) analysis for supervised, non-targeted studies. This approach builds upon the previously reported tile-based F-ratio software for GC×GC-TOFMS data. Cuboid-based F-ratio analysis is enabled by constructing 3D cuboids within the GC3-TOFMS chromatogram and calculating F-ratios for every cuboid on a per-mass channel basis. This methodology is evaluated using a GC3-TOFMS data set of jet fuel spiked with both non-native and native components. The neat and spiked jet fuels were collected on a total-transfer (100 % duty cycle) GC3-TOFMS instrument, employing thermal modulation between the first (1D) and second dimension (2D) columns and dynamic pressure gradient modulation between the 2D and third dimension (3D) columns. In total, cuboid-based F-ratio analysis discovered 32 spiked analytes in the top 50 hits at concentration ratios as low as 1.1. In contrast, tile-based F-ratio analysis of the corresponding GC×GC-TOFMS data only discovered 28 of the spiked analytes total, with only 25 of them in the top 50 hits. Along with discovering more analytes, cuboid-based F-ratio analysis of GC3-TOFMS data resulted in fewer false positives. The increased discoverability is due to the added peak capacity and selectivity provided by the 3D column with GC3-TOFMS resulting in improved chromatographic resolution.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Analyzers: Common Types
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...