Background:
The aim of this study was to evaluate the shear bond strength of three different calcium silicate-based cements (CBCs) with two different bulk-fill composite resins (CRs).
Methods:
Plexiglas moulds with a diameter of 4 mm and a thickness of 2 mm were prepared (n = 60). The Biodentine, NeoPutty and MTA Cem LC samples were randomly divided into two subgroups containing 10 samples each. Surfaces of samples were air dried and Single Bond universal adhesive was applied. Cylindrical plastic capsules of 4 mm height and 2 mm inner diameter belonging to Filtek Bulk-fill and EverX Posterior CRs were centred on coating material and polymerized for 20 s. After shear bond strength (SBS) testing, all samples were examined by scanning electron microscopy (SEM) to identify failure patterns. Three samples, one from each group, were prepared to evaluate chemical composition of CBCs and examined with an energy dispersive X-ray spectroscopy for surface elemental analysis.
Results:
The values obtained from the tests were evaluated as statistically significant (P < 0.05). After SBS testing, the difference between all CBCs was statistically significant in both CRs.
Conclusion:
According to the findings in this study, it was concluded that MTA Cem LC had highest SBS values in both CRs. © 2023 Australian Dental Association.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Bonding and Strength of Aggregate
Hydration of Cement
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Relation Between Tensile Strength and Compressive Strength of Concrete
Additives and Fillers in Concrete
The...