Related Experiment Video
Updated: Jul 17, 2025

Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Achieving imaging and computational reproducibility on multiparametric MRI radiomics features in brain tumor
E-Nae Cheong1, Ji Eun Park2, Seo Young Park3
1Department of Medical Science and Asan Medical Institute of Convergence Science and Technology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Objectives:
The Image Biomarker Standardization Initiative has helped improve the computational reproducibility of MRI radiomics features. Nonetheless, the MRI sequences and features with high imaging reproducibility are yet to be established. To determine reproducible multiparametric MRI radiomics features across test-retest, multi-scanner, and computational reproducibility comparisons, and to evaluate their clinical value in brain tumor diagnosis.
Methods:
To assess reproducibility, T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), and diffusion-weighted imaging (DWI) were acquired from three 3-T MRI scanners using standardized phantom, and radiomics features were extracted using two computational algorithms. Reproducible radiomics features were selected when the concordance correlation coefficient value above 0.9 across multiple sessions, scanners, and computational algorithms. Random forest classifiers were trained with reproducible features (n = 117) and validated in a clinical cohort (n = 50) to evaluate whether features with high reproducibility improved the differentiation of glioblastoma from primary central nervous system lymphomas (PCNSLs).
Results:
Radiomics features from T2WI demonstrated higher repeatability (65-94%) than those from DWI (38-48%) or T1WI (2-92%). Across test-retest, multi-scanner, and computational comparisons, T2WI provided 41 reproducible features, DWI provided six, and T1WI provided two. The performance of the classification model with reproducible features was higher than that using non-reproducible features in both training set (AUC, 0.916 vs. 0.877) and validation set (AUC, 0.957 vs. 0.869).
Conclusion:
Radiomics features with high reproducibility across multiple sessions, scanners, and computational algorithms were identified, and they showed higher diagnostic performance than non-reproducible radiomics features in the differentiation of glioblastoma from PCNSL.
Clinical Relevance Statement:
By identifying the radiomics features showing higher multi-machine reproducibility, our results also demonstrated higher radiomics diagnostic performance in the differentiation of glioblastoma from PCNSL, paving the way for further research designs and clinical application in neuro-oncology.
Key Points:
• Highly reproducible radiomics features across multiple sessions, scanners, and computational algorithms were identified using phantom and applied to clinical diagnosis. • Radiomics features from T2-weighted imaging were more reproducible than those from T1-weighted and diffusion-weighted imaging. • Radiomics features with good reproducibility had better diagnostic performance for brain tumors than features with poor reproducibility.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...