Related Experiment Video
Updated: Jul 17, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
The predictive value of abnormal electrocardiogram for patent foramen ovale: A retrospective study
Peng Jin1, Piqi Jiao1, Juan Feng1
1Department of Cardiovascular Medicine, the 940th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army, Lanzhou, China.
Background And Hypothesis:
The objective of this study was to identify the characteristics of electrocardiogram (ECG) in adult patients with patent foramen ovale (PFO) and to analyze the predictive value of the characteristics of ECG for PFO in adult patients.
Methods:
Retrospectively, 267 patients who had undergone ECG, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE) with agitated saline contrast echocardiography in our hospital, were recruited continuously from January 2021 to March 2023. Electrocardiographs were analyzed to investigate the presence of right bundle branch block (RBBB) and crochetage R wave.
Results:
The ratio of crochetage R wave in inferior leads in patients with PFO was 45.3% and 21.2% without PFO. There were 17 (6.4%) patients with coexistence of crochetage R wave and RBBB, including 13 (6.5%) patients with PFO and four (6.1%) patients without PFO. The accuracies of TTE, crochetage R wave, and RBBB were 0.637, 0.535, and 0.314, respectively. A combination of crochetage R wave and RBBB demonstrated a sensitivity of 0.507 and a specificity of 0.758. When TTE, crochetage R wave, and RBBB were combined, the accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 0.712, 0.801, 0.439, 0.813, and 0.420, respectively. Logistic regression analysis revealed a correlation between PFO and the presence of crochetage R wave (odds ratio [OR]: 3.073, 95% confidence interval [CI]: 1.601-5.899, p < 0.001), and also a combination between crochetage R wave and RBBB (OR: 3.220, 95% CI: 1.720-6.028, p < 0.001).
Conclusions:
Crochetage R wave in ECG was associated with PFO. Crochetage R wave, especially combined with RBBB and TTE, may be helpful in the early detection of patients with PFO.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Mitral Stenosis II: Clinical features and Diagnostic Tests
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Electrophysiology of Normal Cardiac Rhythm