Related Experiment Video
Updated: Jul 17, 2025

Measuring Cardiac Autonomic Nervous System ANS Activity in Children
Published on: April 29, 2013
Correlation between electronic wrist blood pressure with auscultatory blood pressure in children
1Pediatrics Department, Niğde Ömer Halisdemir University Training and Research Hospital, Niğde, Turkey. drzeynoyilmaz@gmail.com.
Objective:
The increasing prevalence of obesity in children and adolescents has turned hypertension into an important public health issue. In the current literature, auscultatory blood pressure measurement is recommended for the diagnosis of hypertension. The number of studies comparing electronic blood pressure measurement and auscultatory blood pressure measurement is limited. This study aimed to compare auscultatory blood pressure measurement with electronic blood pressure measurement in the children population group aged 5-15 years.
Patients And Methods:
A total of 72 patients aged between 5-15 years without chronic disease were included in the study. Anthropometric measurements (height, weight, body mass index, wrist circumference, mid-upper arm circumference) were performed. Systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) were first measured electronically from the wrist using an Omron Rs7 Intelli It HEM-6232T device, and then auscultatory measurements were performed. Each type of measurement was performed 3 times intermittently.
Results:
The mean wrist circumference was 14.43±0.22 cm and the mean mid-upper arm circumference was 21.43±0.55 cm. Mean SBP, DBP and MAP measured electronically on the wrist were 104.1±1.5, 65.6±1.3 and 78.1±1.3 mmHg, respectively, and mean SBP, DBP and MAP measured via auscultation were 99.3±1, 61.4±0.7 and 73.6±0.7 mmHg, respectively. Electronically-measured wrist MAP had significantly moderate correlations with mid-upper arm and wrist circumference (r:0.547, r:0.559, p<0.01).
Conclusions:
Since the differences were less than 4 mmHg in both systolic and diastolic pressures between electronic wrist blood pressure (EWBP) measurement and auscultatory measurement, it appears that electronic measurement may be important in first line of blood pressure screening. Since it is easy and practical to use in the early period, it may be an alternative approach to auscultatory measurement among non-critical pediatric patients.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...