Related Experiment Video
Updated: Jul 17, 2025

The Diffusion of Passive Tracers in Laminar Shear Flow
Published on: May 1, 2018
Computational Fluid Dynamics Study of the Dispersion Caused by Capillary Misconnection in Nano-Flow Liquid
Ali Moussa1, Sander Deridder1, Ken Broeckhoven1
1Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
It is well known that high-speed/high-efficiency separations in nano-flow liquid chromatography (LC) are very sensitive to the quality of the connections between the column and the rest of the instrument. In the present study, two types of connection errors (capillary misalignment and the occurrence of an inter-capillary gap) have been investigated using computational fluid dynamics. Interestingly, it has been found that large degrees of capillary misalignment (assuming an otherwise perfect contact between the capillary end-faces) can be afforded without introducing any significant dispersion over the entire range of investigated relative misalignment errors (0 ≤ ε/dcap ≤ 75%), even at the largest flow rates considered in nano-LC. On the other hand, when an inter-capillary gap is present, the dispersion very rapidly increases with the radial width Dc of this gap (extra variance ∼Dc with n even reaching values above 4). The dependency on the gap length Lc is however much smaller. Results show that, when Dc ≤ 30 μm and Lc ≤ 200 μm, dispersion losses can be limited to the order of 1 nL2 at a flow of 1.5 μL/min, which is generally very small compared to the dispersion in the capillaries (20 μm i.d.) themselves. This result also reconfirms that zero-dead volume connectors with a sufficiently narrow bore can in theory be used without compromising peak dispersion in nano-LC, at least when the capillaries can be matched perfectly to the connector in- and outlet faces. The results are also indicative of the extra dispersion occurring inside microfluidic chips or in the connections between a microfluidic chip and the outer world.
Related Concept Videos
Capillarity in Fluid
Surface tension is crucial to capillarity. It results from cohesive forces between liquid molecules at the liquid-air boundary, forming a skin that resists external forces. When the capillary tube...
Rise of Liquid in a Capillary Tube
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...

