Related Experiment Video
Updated: Jul 17, 2025

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
The Derivation of Epigastric Motion to Assess Neonatal Breathing and Sleep: An Exploratory Study
Guido Stichtenoth1, Niclas Knottnerus-Meyer1, Jonas Helmstetter2
1Department of Pediatrics, University of Lübeck, Lubeck, Germany.
Introduction:
New non-medical monitors are offered for respiration monitoring of neonates. Epigastric motion during sleep was investigated by means of a wearable tracker in parallel to clinical monitoring.
Cohort:
23 hospitalised neonates ready for discharge.
Methods:
A 3-axes-accelerometer and -gyroscope was placed in a standard epigastric position. Between two routine care rounds signals were recorded in parallel to monitoring of impedance pneumography (IP), ECG and pulse oximetry. Motion signals vs. time charts were evaluated using 10-min episodes and semiquantitatively assigned to breathing signal quality, regular breathing, periodic breathing and confounding artefacts. The results were compared with the impedance pneumographic data.
Results:
26 recordings (mean duration: 210 min/infant) were conducted without bradycardia or apnea alarm. The gestational age at birth ranged 28.9 to 41.1 and at recording from 35.6 to 42.3 postmenstrual weeks. Motion patterns of quiet sleep with regular breathing, periodic breathing and active sleep with confounding body movements were found. The longitudinal and transversal gyroscope axes resulted in best signal quality. Periodic breathing was found in up to 80% of episodes and decreased inversely with gestational age showing significantly more periodic breathing in preterm infants. Respiration signals of the gyroscope vs. IP showed a low bias and highly variating frequencies.
Conclusions:
Standardized motion trackers may detect typical neonatal breathing and body-motion-patterns, that could help to classify neonatal sleep. Respiratory rates can only be determined during quiet sleep.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...

