Related Experiment Video
Updated: Jul 17, 2025

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
A Novel RP-HPLC Method for Simultaneous Estimation of Vilanterol Trifenatate, Umeclidinium Bromide and Fluticasone
Shweta Yadav1, Vandana Jain1, Hemant Magar2
1Department of Quality Assurance, Oriental College of Pharmacy, Sanpada, Navi Mumbai 400705, India.
Abstract:
The dry powder inhalation formulation containing vilanterol trifenatate, umeclidinium bromide and fluticasone furoate intended for the therapy of bronchospasm related to chronic obstructive pulmonary disease and bronchial asthma was selected for the development and validation of a novel, selective, accurate, precise, quick and cost-efficient reversed-phase, high-performance liquid chromatography method. Neither an official monograph nor a single method has yet been published for the simultaneous estimation of these three compounds, which makes this method novel. The stationary phase of an ACE-C18-PFP column (250 mm × 4.6 mm, 5 μ) was used with a mobile phase of 25-mM sodium perchlorate buffer (pH 2.5 adjusted with ortho-phosphoric acid) and acetonitrile (40:60% v/v) at a flow rate of 1 mL/min to optimize chromatographic variables. The column temperature was kept at 40°C, and detection was at 224 nm, which was the isosbestic point of these three drugs. Well-resolved good peak symmetry was obtained for all three molecules by isocratic elution in less than 10 min, and the retention times of vilanterol trifenatate, umeclidinium bromide and fluticasone furoate were found to be 3.7, 5.4 and 8.3 min, respectively. The proposed method was validated as per ICH Q2 (R1) guidelines, and the calibration curves were linear in concentration ranges of 5-35 μg/mL for vilanterol trifenatate, 5-80 μg/mL for umeclidinium bromide and 5-150 μg/mL for fluticasone furoate, with mean % recoveries of 99-100%. The limits of detection and quantitation are 0.15 and 0.45 μg/mL for vilanterol trifenatate, 0.58 and 1.77 μg/mL for umeclidinium bromide and 0.32 and 0.96 μg/mL for fluticasone furoate, respectively. Hence, the proposed RP-HPLC technique was successfully used to quantify the inhalation formulation containing all three compounds.
More Related Videos
08:33Radiosynthesis of 1-2-[18F]Fluoroethyl-L-Tryptophan using a One-pot, Two-step Protocol
Published on: September 21, 2021
06:14Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients
Published on: October 15, 2017