Validation of Photoplethysmography Using a Mobile Phone Application for the Assessment of Heart Rate Variability in
Willeke van Dijk1, Anja C Huizink, Mirjam Oosterman
1From the Departments of Clinical, Neuro and Developmental Psychology (van Dijk, Huizink, Lemmers-Jansen) and Clinical Child and Family Studies (Oosterman), Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam; Institute for Brain and Behavior Amsterdam (IBBA), Amsterdam, the Netherlands; Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, United Kingdom (Lemmers-Jansen); and Research Institute of Child Development and Education, University of Amsterdam, Amsterdam, the Netherlands (de Vente).
Objective:
Heart rate variability-biofeedback (HRV-BF) is an effective intervention to reduce stress and anxiety and requires accurate measures of real-time HRV. HRV can be measured through photoplethysmography (PPG) using the camera of a mobile phone. No studies have directly compared HRV-BF supported through PPG against classical electrocardiogram (ECG). The current study aimed to validate PPG HRV measurements during HRV-BF against ECG.
Methods:
Fifty-seven healthy participants (70% women) with a mean (standard deviation) age of 26.70 (9.86) years received HRV-BF in the laboratory. Participants filled out questionnaires and performed five times a 5-minute diaphragmatic breathing exercise at different paces (range, ~6.5 to ~4.5 breaths/min). Four HRV indices obtained through PPG, using the Happitech software development kit, and ECG, using the validated NeXus apparatus, were calculated and compared: RMSSD, pNN50, LFpower, and HFpower. Resonance frequency (i.e., optimal breathing pace) was also compared between methods.
Results:
All intraclass correlation coefficient values of the five different breathing paces were "near perfect" (>0.90) for all HRV indices: lnRMSSD, lnpNN50, lnLFpower, and lnHFpower. All Bland-Altman analyses (with just three incidental exceptions) showed good interchangeability of PPG- and ECG-derived HRV indices. No systematic evidence for proportional bias was found for any of the HRV indices. In addition, correspondence in resonance frequency detection was good with 76.6% agreement between PPG and ECG.
Conclusions:
PPG is a potentially reliable and valid method for the assessment of HRV. PPG is a promising replacement of ECG assessment to measure resonance frequency during HRV-BF.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...