Related Experiment Video
Updated: Jul 17, 2025

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Free-Breathing Compressed Sensing Cine Cardiac MRI for Assessment of Left Ventricular Strain by Feature Tracking in
Ke Xu1, Rong Xu1, Hua-Yan Xu1
1Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
Background:
Cardiac MRI feature-tracking (FT) with breath-holding (BH) cine balanced steady state free precession (bSSFP) imaging is well established. It is unclear whether FT-strain measurements can be reliably derived from free-breathing (FB) compressed sensing (CS) bSSFP imaging.
Purpose:
To compare left ventricular (LV) strain analysis and image quality of an FB CS bSSFP cine sequence with that of a conventional BH bSSFP sequence in children.
Study Type:
Prospective.
Subjects:
40 children able to perform BHs (cohort 1 [12.1 ± 2.2 years]) and 17 children unable to perform BHs (cohort 2 [5.2 ± 1.8 years]).
Field Strength/Sequence:
3T, bSSFP sequence with and without CS.
Assessment:
Acquisition times and image quality were assessed. LV myocardial deformation parameters were compared between BH cine and FB CS cine studies in cohort 1. Strain indices and image quality of FB CS cine studies were also assessed in cohort 2. Intraobserver and interobserver variability of strain parameters was determined.
Statistical Tests:
Paired t-test, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman analysis. A P-value <0.05 was considered statistically significant.
Results:
In cohort 1, the mean acquisition time of the FB CS cine study was significantly lower than for conventional BH cine study (15.6 s vs. 209.4 s). No significant difference were found in global circumferential strain rate (P = 0.089), global longitudinal strain rate (P = 0.366) and EuroCMR image quality scores (P = 0.128) between BH and FB sequences in cohort 1. The overall image quality score of FB CS cine in cohort 2 was 3.5 ± 0.5 with acquisition time of 14.7 ± 2.1 s. Interobserver and intraobserver variabilities were good to excellent (ICC = 0.810 to 0.943).
Data Conclusion:
FB CS cine imaging may be a promising alternative technique for strain assessment in pediatric patients with poor BH ability.
Level Of Evidence:
1 TECHNICAL EFFICACY: Stage 1.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Mitral Stenosis II: Clinical features and Diagnostic Tests