Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Enhanced Stability Differentiation of Therapeutic Polyclonal Antibodies with All Ion Unfolding-Ion Mobility-Mass
Rui Zhao1, Ning Liu1, Zhen Zheng2
1State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Science, Frontiers Science Center for New Organic Matter, College of Chemistry, Nankai University, Tianjin 300071, China.
Abstract:
Compared with monoclonal antibodies, polyclonal antibodies (pAbs) have rather significant characteristics, including lower cost, shorter production cycle, and higher affinity. Therefore, to facilitate their applications in clinic, it is equally critical to comprehensively characterize the conformational stabilities of pAb at the molecular weight-resolved scale, which is technically challenging due to the lack of an effective analytical tool capable of simultaneously providing both stability and molecular weight information within an acceptable error range. Ion mobility-mass spectrometry (IM-MS) has grown as an alternative to rapidly assess protein conformational stability with accurate molecular weight information maintained, especially when equipped with a collision-induced unfolding (CIU) regime. Dynamic and transient conformational intermediates can be captured with the CIU-IM-MS technique, adding to traditional static structural measurements with collisional cross section. Most CIU-IM-MS-centered protocols are focusing on the application to isolated, targeted protein ions, namely, analyzing one single charge state at one time, limiting its analytical throughput and speed. In this study, we employed an enhanced unfolding regime, all ion unfolding (AIU), capable of the simultaneous operation of numerous ions at a time during stepped unfolding processes to analyze pAb. Results show that AIU can quantitatively characterize the subtle differences in conformational stability among four structurally similar pAbs with improved resolving capability by around a 2-4-fold increment in both stability and structure differentiating parameters. Besides, AIU also benefits from considerably saved time cost and improved spectrum quality with an elevated signal-to-noise ratio.
More Related Videos
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018