Accelerated Miocene incision along the Yangtze River driven by headward drainage basin expansion

Alexander Rohrmann1, Eric Kirby2, Wolfgang Schwanghart3

  • 1Institute of Geological Sciences, Freie Universität Berlin, Berlin, Germany.

Science Advances
|September 8, 2023
PubMed

Related Concept Videos

Expansion and Contraction in Masonry Walls01:19

Expansion and Contraction in Masonry Walls

Masonry walls are subject to slight expansion and contraction due to variations in temperature and moisture. Thermal movement in masonry is relatively straightforward to measure and plan for. On the other hand, moisture movement poses more of a challenge. New clay masonry units typically absorb water and expand over time under normal environmental conditions. Conversely, new concrete masonry units tend to shrink as they lose the excess moisture acquired during their production process.
To...
975
Region of Convergence01:17

Region of Convergence

The z-transform is a powerful mathematical tool used in the analysis of discrete-time signals and systems. It is a crucial tool in the analysis of discrete-time systems, but its convergence is limited to specific values of the complex variable z. This range of values, known as the Region of Convergence (ROC), is fundamental in determining the behavior and stability of a system or signal. The ROC defines the region in the complex plane where the z-transform converges, which can take various...
474
M-Cdk Drives Transition Into Mitosis02:15

M-Cdk Drives Transition Into Mitosis

Checkpoints throughout the cell cycle serve as safeguards and gatekeepers, allowing the cell cycle to progress in favorable conditions and slow or halt it in problematic ones. This regulation is known as the cell cycle control system.
Cyclin-dependent kinases, or Cdks, work in concert with cyclins to control cell cycle transitions. M-Cdk, a complex of Cdk1 bound to M cyclin, is a well-known example of this coordinated control that drives the transition from the G2 to the M phase.
M cyclin...
5.6K
Cavity Drainage and Flashings in Masonry walls01:20

Cavity Drainage and Flashings in Masonry walls

Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
104