Biofilm Removal Using Carbon Dioxide Aerosols without Nitrogen Purge
Published on: November 6, 2016
Effect of forceful suction and air disinfection machines on aerosol removal
1Department of hospital allergy, Medical department, Hebei Key Laboratory of Stomatology, Hebei Clinical Research Center for Oral Diseases, School and Hospital of Stomatology, Hebei Medical University, Shijiazhuang, 050017, PR China.
Backgrounds:
Dental procedures involving drilling and grinding can produce a significant amount of suspended aerosol particles (PM) and bioaerosols. This study aims to analyze the size and concentration of aerosol particles generated during drilling and to investigate the effectiveness of two air exchange systems, namely forceful suction (FS) and air disinfection machines (DM), in removing PM.
Methods:
For this study, 100 extracted permanent teeth were collected and divided into three groups: without suction (n = 50), suction with forceful suction (n = 25), and suction with air disinfection machines (n = 25). The removal rate of suspended aerosol particles was analyzed using particle counters and air data multimeter.
Results:
When drilling and grinding were performed without vacuum, 0.75% of the aerosol particles generated were PM2.5-10, 78.25% of total suspended aerosol particles (TSP) were PM2.5, and 98.68% of TSP were PM1. The nanoanalyzer measurements revealed that the aerodynamic diameter of most aerosol particles was below 60 nm, with an average particle diameter of 52.61 nm and an average concentration of 2.6*1011 ultrafine aerosol particles. The air change per hour (ACH) was significantly lower in the air disinfection machines group compared to the forceful suction group. Additionally, the number of aerosol particles and mass concentration was significantly lower in the air disinfection machines group compared to the forceful suction group in terms of PM2.5 levels. However, the forceful suction group also reduced the mass concentration in PM10 level than the air disinfection machines group.
Conclusion:
In conclusion, the air exchange system can reduce the aerosol particles generated during drilling and grinding. Comparing the two air exchange systems, it was found that the air disinfection machines group reduces the number of aerosol particles and mass concentration in PM2.5 levels, while the forceful suction group reduces the mass concentration in PM10 level.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Suctioning II: Procedure