Related Experiment Video
Updated: Jul 16, 2025

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Endovenous Thermal Ablation for Treatment of Symptomatic Saphenous Veins-Does the Body Weight Matter?
Simon Bossart1,2, Patricia Fiona Boesch1, Hak Hong Keo3,4
1Gefässpraxis am See-Lakeside Vascular Center Lucerne, 6003 Lucerne, Switzerland.
Objective:
This study aimed to examine whether body weight may affect the effectiveness and safety of endovenous thermal ablation (ETA) for the treatment of symptomatic varicose veins.
Methods:
This retrospective single-center cohort study analyzed the outcomes and patient demographic data with a focus on the body weight of all patients who had ETA of symptomatic varicose veins between September 2017 and October 2020.
Results:
A total of 1178 treated truncal veins from 636 patients were analyzed. The mean ± standard deviation body mass index (BMI) was 25.5 ± 4.9. In 2.3% of cases, the patients were underweight (BMI < 18.5), 31.0% were overweight (BMI > 25), and 16.6% were obese (BMI > 30). Complete truncal occlusion was observed 1 year post intervention in 97.6-100% and patients were satisfied or very satisfied in 96.2-100% across BMI groups. Pain was low but significantly higher in the patients with obesity 6 weeks post intervention (visual analog scale 0.84 ± 1.49) and a higher infection rate was observed in the patients with obesity (n = 4/132; 3.0%). No significant association was observed between BMI and bleeding or thromboembolic events.
Conclusions:
Patients with obesity experienced prolonged pain and more infections after ETA, but ETA for varicose vein treatment remains effective and safe, independent of the patient's BMI.
More Related Videos
Related Concept Videos
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis IV: Nursing Management
Varicose Veins I: Introduction