Changes in Parameters after High Tibial Osteotomy: Comparison of EOS System and Computed Tomographic Analysis
Hyun-Jin Yoo1, Jae-Kyu Choi1, Youn-Moo Heo1
1Department of Orthopedic Surgery, College of Medicine, Konyang University, 158 Gwanjeodong-ro, Seo-gu, Daejeon 35365, Republic of Korea.
The EOS system accurately measures lower limb alignment changes after medial open-wedge high tibial osteotomy (MOWHTO), similar to CT scans. Distal tibial internal rotation occurred post-MOWHTO, but no factors correlated with this deformation.
Area of Science:
- Orthopedic surgery
- Medical imaging technology
- Biomechanical analysis
Background:
- Medial open-wedge high tibial osteotomy (MOWHTO) can cause unintended distal tibial rotation.
- Computed tomography (CT) is standard for limb alignment but involves radiation.
- The EOS system offers low-dose 3D modeling and automated alignment measurements.
Purpose of the Study:
- To compare lower limb alignment measurements between EOS imaging and CT after MOWHTO.
- To identify factors influencing tibial deformation during MOWHTO.
Main Methods:
- Prospective enrollment of 30 patients undergoing MOWHTO.
- Pre- and post-operative measurements of femoral/tibial torsion, femorotibial rotation, and posterior tibial slope using both CT and EOS.
- Statistical analysis to compare imaging modalities and identify correlating factors.
Main Results:
- No significant differences were found between CT and EOS for tibial torsion or posterior tibial slope, pre- or post-operatively.
- No identified variables correlated significantly with changes in tibial torsion or posterior tibial slope.
- Distal tibial internal rotation was consistently observed after MOWHTO.
Conclusions:
- The EOS system is a viable alternative to CT for measuring key lower limb alignment parameters following MOWHTO.
- While distal tibial internal rotation is common after MOWHTO, its causative factors remain unidentified in this study.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography