Cross-Component Transferable Transformer Pipeline Obeying Dynamic Seesaw for Rotating Machinery with Imbalanced Data
Binbin Xu1, Boquan Ma1, Zheng Yang2
1Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China.
Abstract:
Due to the lack of fault data in the daily work of rotating machinery components, existing data-driven fault diagnosis procedures cannot accurately diagnose fault classes and are difficult to apply to most components. At the same time, the complex and variable working conditions of components pose a challenge to the feature extraction capability of the models. Therefore, a transferable pipeline is constructed to solve the fault diagnosis of multiple components in the presence of imbalanced data. Firstly, synchrosqueezed wavelet transforms (SWT) are improved to highlight the time-frequency feature of the signal and reduce the time-frequency differences between different signals. Secondly, we proposed a novel hierarchical window transformer model that obeys a dynamic seesaw (HWT-SS), which compensates for imbalanced samples while fully extracting key features of the samples. Finally, a transfer diagnosis between components provides a new approach to solving fault diagnosis with imbalanced data among multiple components. The comparison with the benchmark models in four datasets proves that the proposed model has the advantages of strong feature extraction capability and low influence from imbalanced data. The transfer tests between datasets and the visual interpretation of the model prove that the transfer diagnosis between components can further improve the diagnostic capability of the model for extremely imbalanced data.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Instrument Transformers
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...