Wireless, Smart Hemostasis Device with All-Soft Sensing System for Quantitative and Real-Time Pressure Evaluation
Chengjun Zhang1, Qing Yang1, Xianglin Meng2
1School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, P. R. China.
Advanced Science (Weinheim, Baden-Wurttemberg, Germany)
|September 9, 2023
Summary
This study presents a wireless sensor system to monitor pressure during transradial procedures, improving hemostasis and preventing complications. Continuous, objective pressure data aids medical professionals in enhancing surgical quality and patient outcomes.
Area of Science:
- Biomedical Engineering
- Medical Devices
- Wearable Technology
Background:
- Accurate pressure application is crucial for hemostasis after transradial procedures.
- Current subjective pressure assessment can lead to inadequate hemostasis or thrombosis.
- Objective monitoring is needed to optimize pressure management and patient safety.
Purpose of the Study:
- To develop a compact, wireless sensing system for continuous pressure monitoring during transradial procedures.
- To enable real-time data transmission for informed clinical decision-making.
- To improve the quality and safety of transradial interventions.
Main Methods:
- Fabrication of a liquid metal (LM)-based, all-soft pressure sensor for conformal skin attachment.
- Integration of wireless technology for real-time data transmission to mobile devices.
- Testing sensor sensitivity and performance across a wide pressure range (0-100 kPa).
Main Results:
- Achieved linear sensitivity of 0.007 kPa⁻¹ over a 0-100 kPa pressure range.
- Demonstrated real-time wireless data transmission of applied pressure.
- Developed a system for continuous, objective pressure monitoring.
Conclusions:
- The developed wireless sensing system offers a reliable method for objective pressure monitoring in transradial procedures.
- Continuous data collection and analysis can enhance surgical quality and reduce postoperative complications.
- This technology provides a valuable tool for medical assistance and improving patient care.
Related Concept Videos
Equipments Used To Measure Blood Pressure
1.0K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.0K
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K