Related Experiment Video
Updated: Jul 16, 2025

Patterned Photostimulation with Digital Micromirror Devices to Investigate Dendritic Integration Across Branch Points
Published on: March 2, 2011
Establishment of two visual interpretation methods of DIV1 LAMP amplification products
Chen Li1, Kaiting Jiang1, Liang Qiu1
1Key Laboratory of Maricultural Organism Disease Control, Ministry of Agriculture, Function Laboratory for Marine Fisheries Science and Food Production Processes, Qingdao National Laboratory for Marine Science and Technology, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao Key Laboratory of Mariculture Epidemiology and Biosecurity, Qingdao 266071, China.
Abstract:
Viral diseases have become a significant impediment to the sustainable development of the global shrimp aquaculture industry. Decapod iridescent virus 1 (DIV1) is an emerging shrimp virus that has affected shrimp in China recent years. Rapid detection of DIV1 could improve enhance the effectiveness of prevention, control and treatment in the absence of good prevention and control measures. This study established loop-mediated isothermal amplification (LAMP) along with two visual interpretation methods, LAMP-dye and LAMP-LFD, to detect DIV1. The newly developed method would not cause cross-reactions with other shrimp pathogens such as white spot syndrome virus (WSSV), infectious hypodermal and hematopoietic necrosis virus (IHHNV), Enterocytozoon hepatopenaei (EHP), and Vibrio parahaemolyticus acute hepatopancreatic necrosis disease (VpAHPND). The detection limit of DIV1 LAMP was as low as 103 copies of DIV1 per reaction, with a reaction time of less than 40 min. The diagnostic sensitivity and diagnostic specificity of this method were determined to be 88% and 100%, respectively, when compared with the conventional PCR. Both of the LAMP-dye and LAMP-LFD methods are cost-effective and do not require expensive amplification equipment. They can be combined with LAMP and other temperature amplification methods for rapid on-site detection, effectively prevent aerosol contamination, and which are convenient and suitable for field testing or preliminary infection rish prediction experiments to predict the risk of infection.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
10:18Photodiode-Based Optical Imaging for Recording Network Dynamics with Single-Neuron Resolution in Non-Transgenic Invertebrates
Published on: July 9, 2020