Related Experiment Video
Updated: Jul 16, 2025

Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Cannabis profiling of seized samples: An intra-location variability study using gas chromatography-mass spectrometry
Amorn Slosse1,2, Filip Van Durme2, Nele Samyn2
1Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Vrije Universiteit Brussel (VUB), Brussels, Belgium.
Abstract:
Yearly, cannabis belongs to the most seized drugs worldwide. During judicial investigations, illicit cannabis profiling can be performed to compare seized herbal material. However, comparison is challenging because of the natural heterogeneity of the psychoactive crop. Gas chromatography-mass spectrometry (GC-MS) profiles, consisting of eight cannabinoids, were used to study the intra-location (within) and inter-location (between) variabilities. Decision thresholds were derived from the 95% and 99% confidence limits, applying Pearson correlation coefficients for the intra-location samples. The false negatives and false positives (FPs) determined the discriminative power of different pretreatments applied to obtain the lowest FP error rate possible. Initially, a 97 samples data set was used and with log transformation as pretreatment, a decrease in FPs from 38% and 45% FPs to 17% and 22%, for both confidence limits, respectively, was seen relative to internal standard normalization that was used as reference. An additional intra-plantation variability study with 130 samples verified whether the initial model contained sufficient within-location information, but this was not the case. Hence, a combined data matrix was constructed with all seized samples. Log transformation provided the best FP results for both limits, that is, an improvement from 58% and 64% to 21% and 26%, respectively, was seen. The representativeness of these 'linked' thresholds was demonstrated using both cross-validation and an external set, for which similar FP results as for the calibration set were obtained. By applying data pretreatment, a significant improvement was observed to distinguish seized samples. However, the FP rate is still not at an acceptable level to defend in court.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...