Related Experiment Video
Updated: Jul 16, 2025

Data Acquisition and Analysis In Brainstem Evoked Response Audiometry In Mice
Published on: May 10, 2019
Study of Auditory Brainstem Evoked Response at Varying Frequencies in Subclinical Hypothyroid Subjects
Indira Jha1, Kabir Alam1, Kaushal K Keshari1
1Department of Physiology, IGIMS, Patna, Bihar, India.
Background:
Hearing deterioration in hypothyroid subject was documented by Kemp. Cristiane et al. reported delayed waves latency in subclinical hypothyroid subjects. Recording of auditory brain stem evoked response in subclinical hypothyroid subjects at 80 dB and varying frequencies has been done.
Materials And Methods:
Case control study. Group 1, N = 30 control subjects, free T3, free T4, thyroid stimulating hormone (TSH) within normal range. Group 2, N = 30 subclinical hypothyroid subjects, TSH was between 4.6-8 microIU/L. Student Unpaired t test was done. Those on epileptic, neuroleptics, depression, psychosis drugs, inflammatory, proliferative, traumatic ear disorder, smokers, on tobacco, COVID-19 positive subjects, altered sensorium, drug abuse, diabetes mellitus, neuropathy, hypertension, cardiac arrhythmia, family history of hearing disorder, and furosemide drug were excluded. Auditory brainstem evoked response (ABER) done.
Results:
Mean ± SD of Brainstem evoked response auditory (BERA) waves III, V, interpeak latencies at 80 dB, 2, 4,6 KHz reported delay and significant in subclinical hypothyroid group as compared to control.
Conclusion:
BERA study at 6 KHz and 80 dB detects central neuropathy earlier in subclinical hypothyroid patients.
Related Concept Videos
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...