Related Experiment Video
Updated: Jul 16, 2025

Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
The Water Swallow Test and EAT-10 as Screening Tools for Referral to Videofluoroscopy
Jonna Kuuskoski1, Jaakko Vanhatalo2, Jami Rekola1
1Department of Otorhinolaryngology - Head and Neck Surgery, Turku University Hospital and University of Turku, Turku, Finland.
Background:
Videofluoroscopy (VFS) is the gold standard in evaluating dysphagia. Water swallow tests (WST) and the Eating Assessment Tool (EAT-10) are commonly used in dysphagia screening. We aimed to determine the feasibility of WST and EAT-10 as screening tools for referral to VFS.
Methods:
Patients (n = 150, median age: 70.0 years, range: 19-92 years, 58.7% female) referred to VFS completed the WST and EAT-10 before the examination. In the WST, we evaluated both the qualitative parameters (coughing, possible change in voice) and quantitative parameters (average drinking bolus size, swallowing speed). Correlations of EAT-10 total scores and WST parameters to the VFS findings were analyzed both individually and combined.
Results:
In the WST, the most specific (89.7%) predictor of normal VFS findings was the absence of coughing, and the most sensitive (79.1%) parameter to predict abnormal findings was a bolus size of ≤20 mL. Using a combination of coughing and a bolus size ≤20 mL (simplified WST), the sensitivity of predicting abnormal findings increased to 83.5%. The most sensitive (84.6%) predictor of penetration/aspiration was failing any parameter in the WST. Lack of coughing indicated an absence of penetration/aspiration with an 82.5% specificity. Swallowing speed or combining the EAT-10 results with the WST results did not enhance the sensitivity or specificity of the WST for predicting the VFS results.
Conclusions:
Coughing and average drinking bolus size are the most important parameters in WST when screening for referral to VFS, whereas the swallowing speed does not seem to be useful. The WST is superior to EAT-10 in predicting VFS findings.
Level Of Evidence:
4 Laryngoscope, 134:1349-1355, 2024.
Related Concept Videos
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Serum Laboratory Studies, Stool Test, Breath Test