Related Experiment Video
Updated: Jul 16, 2025

Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Performance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of
Ana Spataru1,2, Paola Eiben3, Annette Pluddemann4
1Department of Neurocritical Care, Southampton General Hospital, Hampshire, SO164YO, UK. ana.spataru@nhs.net.
Abstract:
Closed-loop drug delivery systems are autonomous computers able to administer medication in response to changes in physiological parameters (controlled variables). While limited evidence suggested that closed-loop systems can perform better than manual drug administration in certain settings, this technology remains a research tool with an uncertain risk/benefit profile. Our aim was comparing the performance of closed-loop systems with manual intravenous drug administration in adults. We searched MEDLINE, CENTRAL, and Embase from inception until November 2022, without restriction to language. We assessed for inclusion randomised controlled trials comparing closed-loop and manual administration of intravenous drugs in adults, intraoperatively or in the Intensive Care Unit. We identified 32 studies on closed-loop administration of propofol, noradrenaline, phenylephrine, insulin, neuromuscular blockers, and vasodilators. Most studies were at moderate or high risk of bias. The results showed that closed-loop systems reduced the duration of blood pressure outside prespecified targets during noradrenaline (MD 14.9%, 95% CI 9.6-20.2%, I2 = 66.6%) and vasodilators administration (MD 7.4%, 95% CI 5.2-9.7%, I2 = 62.3%). Closed-loop systems also decreased the duration of recovery after propofol (MD 1.3 min, 95% CI 0.4-2.1 min, I2 = 58.6%) and neuromuscular blockers (MD 9.0 min, 95% CI 7.9-10.0 min, I2 = 0%). The certainty of the evidence was low or very low for most outcomes. Automatic technology may be used to improve the hemodynamic profile during noradrenaline and vasodilators administration and reduce the duration of postanaesthetic recovery.Registration: This systematic review was registered with PROSPERO (CRD42022336950) on the 7th of June 2022.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...