Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients
Misaki Ito1,2, Koichi Chida2,3, Shu Onodera1
1Department of Radiology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan.
Abstract:
Children are sensitive to radiation; therefore, it is necessary to reduce radiation dose as much as possible in pediatric patients. In addition, it is crucial to investigate the optimal imaging conditions as they considerably affect the radiation dose. In this study, we investigated the effect of different imaging conditions on image quality and optimized the imaging conditions for dental cone-beam computed tomography (CBCT) examinations to diagnose ectopic eruptions and impacted teeth in children. To achieve our aims, we evaluated radiation doses and subjective and objective image quality. The CBCT scans were performed using 3D Accuitomo F17. All combinations of a tube voltage (90 kV), tube currents (1, 2, 3 mA), fields of view (FOVs) (4 × 4, 6 × 6 cm), and rotation angles (360°, 180°) were used. Dose-area product values were measured. SedentexCT IQ cylindrical phantom was used to physically evaluate the image quality. We used the modulation transfer function as an index of resolution, the noise power spectrum as an index of noise characteristics, and the system performance function as an overall evaluation index of the image. Five dentists visually evaluated the images from the head-neck phantom. The results showed that the image quality tended to worsen, and scores for visual evaluation decreased as tube currents, FOVs and rotation angles decreased. In particular, image noise negatively affected the delineation of the periodontal ligament space. The optimal imaging conditions were 90 kV, 2 mA, 4 × 4 cm FOV and 180° rotation. These results suggest that CBCT radiation doses can be significantly reduced by optimizing the imaging conditions.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...