Related Experiment Video
Updated: Jul 16, 2025

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Qualitative use of ICG angiography and lymphography in periorbital surgery
Ann Q Tran1, Royce B Park1, Daniel K Lee1
1Department of Ophthalmology, Illinois Eye and Ear Infirmary, University of Illinois at Chicago, Chicago, Illinois, USA.
Purpose:
Open imaging fluorescence devices have been utilized in surgical oncology, vascular and plastic surgery; however, the role of indocyanine green (ICG) in periorbital surgery and lymphatics has not been explored.
Methods:
A prospective, single-center diagnostic study was conducted from 2021 to 2022 utilizing ICG to assess both the periorbital vasculature and lymphatics. Fluorescence was captured with open-imaging fluorescent devices. For ICG angiography, a total of 5-10 mg of ICG was given intravenously at various time points to visualize intraoperative blood flow to eyelid flaps, vascular tumors, or extraocular muscles. For ICG lymphography, 0.03-0.06 mg of ICG was injected subcutaneously to visualize the periorbital and facial lymphatic drainage.
Results:
Twenty-two patients underwent ICG angiography. Periorbital vascular supply was seen in eyelid reconstructions (n = 8), anophthalmic reconstructions (n = 2), lacrimal gland tumors (n = 2), orbital venous malformations (n = 2), tumor metastasis (n = 1) and benign tumors (n = 1). The anterior ciliary arteries were visualized to the extraocular muscles in fracture repairs (n = 3) and muscle biopsies (n = 2). Ten patients underwent ICG lymphangiography highlighting the global periorbital lymphatic system.
Conclusion:
ICG allows for visualization of the vasculature of extraocular muscles and tumors, assessing perfusion of flaps during reconstruction and the global periorbital lymphatic drainage pathways.