Real-world evidence on the association between cardiac implantable electronic device infection and all-cause
Md Shajedur Rahman Shawon1, Oluwadamisola Temilade Sotade1, Michelle Hill2
1Centre for Big Data Research in Health, University of New South Wales, Level 2, AGSM Building (G27), Sydney, NSW 2052, Australia.
Aims:
An infection following cardiac implantable electronic device (CIED) procedure is a serious complication, but its association with all-cause mortality is inconsistent across observational studies. To quantify the association between CIED infection and all-cause mortality in a large, contemporary cohort from New South Wales, Australia.
Methods And Results:
This retrospective cohort study used linked hospital and mortality data and included all patients aged >18 years who underwent a CIED procedure between July 2017 and September 2022. Cardiac implantable electronic device infection was defined by the presence of relevant diagnosis codes. Cox regression to estimate adjusted hazard ratios (aHRs) with 95% confidence intervals (CIs) for the association of CIED infection with mortality, at 1-year, and at the end of follow-up, with CIED infection included as a time-dependent variable, and other potential risk factors for mortality included as fixed covariates. We followed 37,750 patients with CIED procedures {36% female, mean age [standard deviation (SD)] 75.8 [12.7] years}, and 487 (1.3%) CIED infections were identified. We observed 5771 (15.3%) deaths during an average follow-up of 25.2 (SD 16.8) months. Compared with no infection group, patients with CIED infection had a higher Kaplan-Meier mortality rate (19.4 vs. 6.8%) and adjusted hazard of mortality (aHR 2.73, 95% CI 2.10-3.54) at 12 months post-procedure. These differences were attenuated but still remained significant at the end of follow-up (aHR 1.83, 95% CI 1.52-2.19).
Conclusion:
In a complete, state-wide cohort of CIED patients, infection was associated with higher risks of both short-term and long-term mortality.