Related Experiment Video
Updated: Jul 16, 2025

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
Comparison of ultrasound elastography, magnetic resonance elastography and finite element model to quantify nonlinear
Gwenaël Pagé1, Marion Bied1, Philippe Garteiser2
1BioMaps, Laboratoire d'Imagerie Biomédicale Multimodale, Université Paris-Saclay, CEA, CNRS UMR 9011, Inserm UMR 1281, Service hospitalier Frédéric Joliot, F-91401 Orsay, France.
Abstract:
Objective. The aim of this study is to validate the estimation of the nonlinear shear modulus (A) from the acoustoelasticity theory with two experimental methods, ultrasound (US) elastography and magnetic resonance elastography (MRE), and a finite element method.Approach. Experiments were performed on agar (2%)-gelatin (8%) phantom considered as homogeneous, elastic and isotropic. Two specific setups were built to ensure a uniaxial stress step by step on the phantom, one for US and a nonmagnetic version for MRE. The stress was controlled identically in both imaging techniques, with a water tank placed on the top of the phantom and filled with increasing masses of water during the experiment. In US, the supersonic shear wave elastography was implemented on an ultrafast US device, driving a 6 MHz linear array to measure shear wave speed. In MRE, a gradient-echo sequence was used in which the three spatial directions of a 40 Hz continuous wave displacement generated with an external driver were encoded successively. Numerically, a finite element method was developed to simulate the propagation of the shear wave in a uniaxially stressed soft medium.Main results. Similar shear moduli were estimated at zero stress using experimental methods,μ0US= 12.3 ± 0.3 kPa andμ0MRE= 11.5 ± 0.7 kPa. Numerical simulations were set with a shear modulus of 12 kPa and the resulting nonlinear shear modulus was found to be -58.1 ± 0.7 kPa. A very good agreement between the finite element model and the experimental models (AUS= -58.9 ± 9.9 kPa andAMRE= -52.8 ± 6.5 kPa) was obtained.Significance. These results show the validity of such nonlinear shear modulus measurement quantification in shear wave elastography. This work paves the way to develop nonlinear elastography technique to get a new biomarker for medical diagnosis.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Elastic Strain Energy for Shearing Stresses
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Shearing Strain
Strain and Elastic Modulus
Elasticity in Concrete

