Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

4.8K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
4.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Motion-aware imaging flow cytometry framework for robust counting and tracking of cells with non-uniform velocities in microfluidics.

Applied optics·2026
Same author

From the Clinic, to the Clinic: Improving the Fluorescent Imaging Quality of ICG via Amphiphilic NIR-IIa AIE Probe.

Biosensors·2026
Same author

EdgePhase: a portable edge-computational microscope for point-of-care quantitative phase imaging.

Optics express·2025
Same author

A Camera-Like Dual-Defocus Curvature Wavefront Sensor With GPU Acceleration for Real-Time Quantitative Phase Imaging.

Microscopy research and technique·2025
Same author

Dual-View Transport of Intensity Phase Imaging-Based Flow Cytometry for Label-Free Cell Analysis and Classification.

Journal of biophotonics·2025
Same author

Mitigating reconstruction errors in extended-ptychography with adaptive scanning position correction.

Applied optics·2025
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jul 16, 2025

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
09:43

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping

Published on: March 20, 2017

9.9K

Dual-channel binary diffuser-based coherent modulation imaging.

Aihui Sun, Feng Gao, Pengfei Zhu

    Applied Optics
    |September 14, 2023
    PubMed
    Summary
    This summary is machine-generated.

    A new dual-channel method enhances binary diffuser-based coherent modulation imaging (CMI). This approach reconstructs both reflected and transmitted light, improving image quality and speed for quantitative phase imaging.

    More Related Videos

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
    09:57

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

    Published on: July 25, 2022

    4.0K
    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
    12:54

    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

    Published on: October 2, 2021

    3.3K

    Related Experiment Videos

    Last Updated: Jul 16, 2025

    Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
    09:43

    Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping

    Published on: March 20, 2017

    9.9K
    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy
    09:57

    Multiplex Chemical Imaging Based on Broadband Stimulated Raman Scattering Microscopy

    Published on: July 25, 2022

    4.0K
    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
    12:54

    Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

    Published on: October 2, 2021

    3.3K

    Area of Science:

    • Optics
    • Image Reconstruction
    • Diffractive Optics

    Background:

    • Binary diffuser-based coherent modulation imaging (CMI) is a technique for quantitative phase imaging.
    • Traditional CMI methods often utilize single-channel optical alignments, potentially limiting the captured information.

    Purpose of the Study:

    • To enhance the performance of binary diffuser-based CMI.
    • To introduce a novel dual-channel optical alignment for improved imaging.

    Main Methods:

    • Proposed a double-channel optical alignment for CMI.
    • Simultaneously captured diffraction patterns from both reflection and transmission of a binary diffuser.
    • Employed iterative reconstruction combining information from both channels.
    • Developed dual-channel binary diffuser-based coherent modulation imaging (DB-CMI).

    Main Results:

    • Successfully reconstructed information from reflected light, previously unutilized in single-channel CMI.
    • Achieved improved reconstruction quality compared to traditional methods.
    • Demonstrated enhanced reconstruction speed.
    • Verified improvements through numerical simulations and experimental validation.

    Conclusions:

    • Dual-channel binary diffuser-based coherent modulation imaging (DB-CMI) significantly improves upon traditional CMI.
    • DB-CMI offers a powerful and effective tool for quantitative phase imaging applications.
    • The proposed method enhances both the quality and efficiency of phase imaging.