Related Experiment Video
Updated: Jul 16, 2025

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Experimental comparison between photoconductive and graphene-based photogating detection in a UV-A region
Abstract:
Photoconductive detectors that use intrinsic absorbent materials include a wide range of detectors. In this paper, a photoconductive detector is fabricated using a titanium dioxide (T i O 2) thin film. The mechanism of the photodetector is changed to the photogating mechanism by transferring monolayer graphene onto the T i O 2 thin film, which shows a great responsivity with a slight change in the fabrication process. Since the maximum responsivity can be obtained by applying and adjusting the gate voltage, the gate voltage is set in all experiments, and the effect of the gate voltage is investigated in both detectors. It is observed that by increasing the gate voltage, the responsivity of the photogating detector increases to 40 A/W at a gate voltage of 15 V. However, in the photoconductive detector, the increase in the gate voltage does not have a particular effect on the detector responsivity. In the photogating detector, the increase in the responsivity due to the increase in the gate voltage is attributed to applying the gate voltage to the graphene layer and not the absorber layer. The efficiency of both detectors is confirmed up to a frequency of 5 kHz.
More Related Videos
Related Concept Videos
UV–Vis Spectrometers
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...