Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

676
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
676
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

681
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
681
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

79
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
79
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

720
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
720
NMR Spectrometers: Overview01:20

NMR Spectrometers: Overview

1.1K
NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
1.1K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

837
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
837

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Efficacy and safety of the single-dose pegylated G-CSF vs. daily G-CSF for peripheral blood stem cells mobilization in donors: a multicenter, randomized controlled trial.

Frontiers in immunology·2026
Same author

Photocatalytic Remote Radical-Polar Crossover Reaction: Access of Organofluorine Compounds via 1,2-Carbonyl Migration.

Organic letters·2026
Same author

Hollow cubic-phase modulated radial coherent beam propagation in atmospheric turbulence: emission efficiency and echo enhancement with Cassegrain systems.

Optics express·2026
Same author

Hypoxia-driven T cell-macrophage-stromal cross-talk sustains fibrosis in preclinical models of cutaneous chronic graft-versus-host disease.

Science translational medicine·2026
Same author

A novel c-Met inhibitor containing chiral pyrrolidine side chain and its application as anti-tumor agents.

European journal of medicinal chemistry·2026
Same author

Ubiquitination of DDX21 by HERC2 induces a dormancy-like phenotype via the NUCKS1-p21/p27 axis to promote radio-resistance in colorectal cancer cells.

Cell death & disease·2026

Related Experiment Video

Updated: Jul 16, 2025

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
09:13

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

Published on: April 21, 2013

27.9K

Neural network-aided optimisation of a radio-frequency atomic magnetometer.

Han Yao, Benjamin Maddox, Ferruccio Renzoni

    Optics Express
    |September 15, 2023
    PubMed
    Summary

    This study introduces an automated method using neural networks to optimize the performance of sensitive magnetic field sensors. By training a model on limited experimental data, the system identifies the best operating settings without human help, achieving high precision in magnetic field detection.

    Keywords:
    machine learning physicsautomated sensor calibrationmagnetic field sensingregression modeling

    Frequently Asked Questions

    More Related Videos

    Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
    09:43

    Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement

    Published on: November 7, 2017

    9.5K
    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
    07:42

    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

    Published on: July 20, 2022

    2.8K

    Related Experiment Videos

    Last Updated: Jul 16, 2025

    Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
    09:13

    Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures

    Published on: April 21, 2013

    27.9K
    Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
    09:43

    Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement

    Published on: November 7, 2017

    9.5K
    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
    07:42

    Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

    Published on: July 20, 2022

    2.8K

    Area of Science:

    • Applied physics and instrumentation research within radio-frequency atomic magnetometer development
    • Computational intelligence and machine learning applications in experimental physics

    Background:

    Precise magnetic field detection often requires complex manual tuning of sensor parameters to achieve peak performance. No prior work had resolved the difficulty of maintaining these settings in remote or inaccessible environments. Standard optimization techniques frequently demand large datasets that are costly or time-consuming to collect during real-world operations. That uncertainty drove the need for more efficient, automated approaches to sensor calibration. Researchers have long sought ways to minimize human intervention while maximizing the sensitivity of these sophisticated devices. Existing methods often fail when experimental data remains sparse or noisy. This gap motivated the exploration of advanced computational tools capable of learning from limited information. The current landscape necessitates a shift toward autonomous systems that can adapt to changing conditions without constant oversight.

    Purpose Of The Study:

    The aim of this research is to develop an efficient, unsupervised method for optimizing the performance of atomic magnetometers. Many practical applications require these sensors to function in environments where human operators cannot provide direct tuning. The authors address the challenge of extracting optimal operating conditions from limited experimental datasets. This problem necessitates a robust automated regression technique to maintain sensor precision. The study proposes using general regression neural networks to bridge the gap between sparse data and peak sensitivity. By automating the calibration process, the researchers seek to eliminate the reliance on manual intervention. The motivation stems from the need for reliable, high-performance sensing in diverse and often inaccessible settings. This work explores how computational intelligence can enhance the utility of sensitive magnetic field detection hardware.

    Main Methods:

    The review approach involves implementing a general regression neural network to manage sensor parameters autonomously. Investigators collect a restricted set of measurements to train the computational model. This design focuses on establishing a functional relationship between physical inputs and the resulting device sensitivity. The team selects cell temperature, pump beam power, and probe beam power as the primary variables for the mapping process. By utilizing this architecture, the system avoids the need for massive training sets. The approach prioritizes efficiency by leveraging the inherent strengths of regression models in sparse data environments. Researchers evaluate the performance by comparing the predicted optimal settings against actual device output. This methodology ensures that the sensor maintains high precision without manual adjustments from an operator.

    Main Results:

    Key findings from the literature indicate that the neural network successfully identifies optimal operating conditions using minimal experimental input. The system achieves an AC sensitivity of 44 fT/Hz at a frequency of 26 kHz. This result demonstrates the efficacy of the model in navigating complex parameter spaces. The mapping between the three input variables and the output sensitivity proves highly accurate. Data suggests that the automated process matches or exceeds the performance of traditional manual tuning methods. The researchers observe that the model remains stable even when the training sample size is kept small. These outcomes confirm that the regression approach is well-suited for unshielded sensor environments. The findings highlight the potential for integrating machine learning into standard hardware calibration workflows.

    Conclusions:

    The researchers demonstrate that general regression neural networks provide a viable pathway for autonomous sensor calibration. This approach successfully maps complex input variables to specific output performance metrics without human guidance. The study confirms that limited data samples suffice for training these models effectively. Synthesis and implications suggest that this framework could be applied to various sensor types beyond the tested configuration. The authors note that the achieved sensitivity highlights the potential for high-performance operation in unshielded environments. Future implementations may benefit from the model's ability to operate with minimal computational overhead. The findings establish a clear link between machine learning integration and improved hardware efficiency. This work provides a foundation for developing fully autonomous magnetic sensing platforms in diverse fields.

    The researchers propose using a general regression neural network to map three inputs—cell temperature, pump beam power, and probe beam power—to the AC sensitivity output. This mechanism enables autonomous optimization, achieving a sensitivity of 44 fT/Hz at 26 kHz without requiring human intervention.

    The authors utilize a general regression neural network, which is specifically chosen for its ability to perform robust regression when provided with only a small sample of experimental data. This tool serves as the primary computational component for the automated tuning process.

    The authors state that an unshielded configuration is necessary to demonstrate the practical utility of the model in real-world conditions. This setup presents a more challenging environment for sensitivity optimization compared to shielded alternatives, thereby validating the robustness of the neural network approach.

    The researchers use a small sample of experimental data as the input for the neural network. This data type is critical because it allows the model to learn optimal operating conditions efficiently, avoiding the need for extensive datasets that are often impractical to obtain.

    The study measures the AC sensitivity of the device, reaching a value of 44 fT/Hz at a frequency of 26 kHz. This measurement serves as the primary indicator of successful optimization through the automated regression process.

    The authors propose that this automated framework effectively removes the requirement for direct operator intervention. They claim this is a significant improvement for applications where manual tuning is not feasible, such as in remote or inaccessible sensor deployments.