Related Experiment Video
Updated: Jul 16, 2025

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Stacked implantation of two prosthetic iris devices for patients with iris defects: A modified surgical technique
David Ethan Rabinovitch1, Ralf Buhrmann2, Devesh K Varma3,4
1Sackler School of Medicine, Tel Aviv University, 35 Klatzkin Street, Tel Aviv, Israel.
Purpose:
Iris pigment deficiency in patients with oculocutaneous albinism (OCA) often causes debilitating photophobia, which is routinely managed by sequential intracapsular insertion of two aniridia rings. A common concern of this technique is the risk of segment interdigitation, which can lead to intraoperative complications.
Observations:
In this report, we describe a modified technique through which both rings were stacked together and inserted simultaneously in a 62-year-old male patient with oculocutaneous albinism and a mild cataract. The patient underwent bilateral phacoemulsification followed by implantation of two Morcher 50E aniridia rings simultaneously, prior to IOL implantation behind the implants within the capsular bag. Post-operatively, the patient's photophobia improved dramatically, and there were no post-operative complications.
Conclusions And Importance:
Simultaneous insertion of two stacked aniridia rings prior to IOL implantation was a safe and successful alternative surgical method for the management of photophobia in patients with oculocutaneous albinism and cataracts.