Related Experiment Video
Updated: Jul 16, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Exploring thermal isomerisation in gas chromatography analyses using natural pyrethrins: Comparison of comprehensive
Neil Andrew Byrnes1, Yuesong Wu1, Yada Nolvachai2
1Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
Abstract:
This study aims to assess and qualitatively compare the visual presentation of chromatographic data from the isomerisation of natural pyrethrins - a group of pesticides derived from Chrysanthemum flowers - using one-dimensional gas chromatography (1DGC) and comprehensive two-dimensional gas chromatography (GC×GC). Molecular structural changes, such as thermal isomerisation in this case, occur during gas chromatography injection and separation, to provide characteristic patterns which may not be routinely recognised on the 1D chromatogram. To demonstrate the influence of analytical method parameters on isomerisation processes, variations in oven temperature (isothermal vs. temperature programmed analysis), inlet mode (split vs. splitless), inlet temperature, and carrier gas flow rate were investigated. Increasing oven temperature was the most significant factor affecting isomerisation. Splitless injection mode and increasing inlet temperature promoted isopyrethrin formation, while the effect of inlet temperature appeared minimal with a split injection technique, most likely due to the short residence time in the inlet. Increased carrier gas flow rates in a temperature programmed analysis reduced retention time and minimised isomerisation. The unique presentation of isopyrethrin peaks on a GC×GC contour plot allows for facile recognition of isomerisation especially at low concentrations, simplifies chromatogram interpretation, and aids in analyte identification. It also confirms that the isomerisation process is irreversible since the pyrethrin I and II compounds are absent throughout the bridge formation. These benefits support the use of GC×GC over 1DGC to study isomerisation. Additionally, due to limited data in the literature, Kováts retention indices and linear retention indices of the natural pyrethrins, including isopyrethrins, were experimentally determined on four columns: DB-5 ms UI, Rxi-17Sil MS, SLB-IL60i, and SLB-IL111i.
More Related Videos
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II