Related Experiment Video
Updated: Jul 16, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Association of forced oscillation technique measurements with respiratory system compliance and resistance in a
Valentin Cerfeuillet1, Laurine Allimonnier1, Sandrine Le Guellec1
1Centre d'étude des pathologies respiratoires / Inserm UMR1100, Université de Tours, Tours, France.
Background:
The forced oscillation technique (FOT) may be useful for diagnosis and follow-up of respiratory diseases. It is unclear how global or regional alterations in airway resistance (Raw) and lung compliance (CL) alter FOT measurements.
Methods:
A 2-compartment physical model of the respiratory system allowed to simulate variations in Raw, CL, and their heterogeneity during tidal breathing in an adult human. Five-Hz respiratory system resistance (Rrs5) and reactance (Xrs5), area of reactance (AX), resonance frequency (Fresp) and intrabreath variation in Rrs5 and Xrs5 were measured by FOT. Frequency dependance of resistance could not be studied in this model. Relationships between model characteristics (Raw, CL, and heterogeneity) and FOT measurements were explored by multiple regression.
Results:
Rrs5 and intrabreath variation in Rrs5 and Xrs5 strongly associated with model characteristics (R2=0.753, 0.5 and 0.658). Associations of Xrs5, AX, and Fresp with model characteristics were weak (R2=0.214, 0.349 and 0.076). Raw heterogeneity was the main determinant of Rrs5 (Coeff=0.594), AX (Coeff=0.566) and intrabreath variation in Rrs5 and Xrs5 (Coeff=0.586 and 0.732). Regional extremes in Raw strongly determined Rrs5 (Coeff=1.006). Xrs5 did not strongly associate with any model characteristic.
Conclusion:
Raw heterogeneity and maximal regional Raw were the main determinants of FOT measurements, in particular Rrs5. Associations between CL and FOT measurements were weak.
Related Concept Videos
Respiratory Volumes and Capacities I
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Volumes and Capacities
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...