An evaluation of the NUI Compact Chest Compression Device (NCCD), a mechanical CPR device suitable for use in the
Andrew Tabner1,2,3, Philip Bryson4, Nicholas Tilbury1
1University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK.
Introduction:
Provision of manual chest compressions in a diving bell using a conventional technique is often impossible, and alternative techniques are poorly evidenced in terms of efficacy and sustainability. The first mechanical cardiopulmonary resuscitation (CPR) device suitable for use in this environment, the NUI Compact Chest Compression Device (NCCD), has recently been designed and manufactured. This study assessed both the efficacy of the device in delivering chest compressions to both prone and seated manikins, and the ability of novice users to apply and operate it.
Methods:
Compression efficacy was assessed using a Resusi Anne QCPR intelligent manikin, and the primary outcome was the proportion of compressions delivered to target depth (50-60 mm). The gold standard was that achieved by expert CPR providers delivering manual CPR; the LUCAS 3 mCPR device was a further comparator.
Results:
The NCCD delivered 100% of compressions to target depth compared to 98% for the gold standard (interquartile range 1.5%) and 98% for the LUCAS 3 when applied to both supine and seated manikins. The NCCD sometimes became dislodged and had to be reapplied when used with a seated manikin.
Conclusions:
The NCCD can deliver chest compressions at target rate and depth to both supine and seated manikins with efficacy equivalent to manual CPR and the LUCAS 3. It can become dislodged when applied to a seated manikin; its design has now been altered to prevent this. New users can be trained in use of the NCCD quickly, but practise is required to ensure effective use.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Buoyancy and Stability for Submerged and Floating Bodies
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Buoyancy
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...