Related Experiment Video
Updated: Jul 16, 2025

Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
A 3 mm Port Reduces Postoperative Pain After Laparoscopic Colon Cancer Surgery: A Case-control Matched Study
Jin Sun Choi1, Hyo Jun Kim2, Han-Ki Lim2
1Department of Surgery, SMG-SNU Boramae Medical Centera.
Background:
Recently, smaller-size trocars and instruments have been developed for laparoscopic colon cancer surgery; however, their effectiveness and safety have not been elucidated. This study aimed to investigate whether 3 mm trocars and instruments have benefits compared with conventional trocars and instruments.
Patients And Methods:
Patients with colon cancer who underwent laparoscopic anterior resection or right hemicolectomy were included. Patients who underwent combined resections of other organs and those with conversion to open surgery were excluded. In the 3 mm group, three 5 mm trocars were replaced by 3 mm trocars. The numeric rating scale (NRS) immediately postoperatively at 24, 48, and 72 hours, respectively, after surgery and the use of additional analgesics and perioperative outcomes were analyzed. Case-control matched analysis was used to reduce bias according to the type of surgery.
Results:
A total of 207 patients (conventional: n = 158, 3 mm: n = 49) were included. Before matching, NRS 48 hours postoperatively ( P = 0.049), proportion of patients using additional intravenous (IV) analgesics ( P = 0.007), postoperative hospital stay ( P < 0.001), and blood loss ( P < 0.001) were lower in the 3 mm group. In multivariable analysis, trocar type significantly impacted the proportion of patients using additional IV analgesics (odds ratio: 0.330; 95% CI: 0.153-0.712; P = 0.005). After case-control matching, NRS immediately postoperatively ( P = 0.015) and 24 hours postsurgery ( P = 0.043), patients using additional IV analgesics ( P = 0.019), postoperative hospital stay ( P = 0.010), intraoperative blood loss ( P < 0.001), and postoperative complication rate ( P = 0.028) were significantly lower in the 3 mm group compared with the 5 mm group.
Conclusions:
The use of 3 mm trocars and instruments in laparoscopic colon cancer surgery can effectively reduce postoperative pain while maintaining perioperative safety.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Peripheral Artery Disease V: Postoperative Nursing Management