Utilizing patient-specific 3D printed kidney surgical guide with realistic phantom for partial nephrectomy.
Junhyeok Ock1,2, Taehun Kim1,3, Sungchul On1,2
1Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Scientific Reports
|September 19, 2023
Summary
A novel 3D-printed kidney surgical guide (3DP-KSG) enables precise localization of renal cell carcinoma (RCC) for partial nephrectomy. This 3DP-KSG facilitates accurate tumor removal, preserving kidney function during surgery.
Area of Science:
- Urology
- Surgical Technology
- Medical Imaging
Background:
- Partial nephrectomy preserves renal function better than radical nephrectomy for localized renal cell carcinoma (RCC).
- Accurate intraoperative localization of RCC is challenging, hindering precise tumor excision.
- Computed tomography (CT) aids in identifying RCC but lacks direct intraoperative guidance.
Purpose of the Study:
- To develop and evaluate a 3D-printed kidney surgical guide (3DP-KSG) for accurate RCC targeting.
- To assess the precision of catheter insertion guided by the 3DP-KSG in realistic kidney phantoms.
- To determine the feasibility of using 3DP-KSG for quantitative and immediate RCC marking during surgery.
Main Methods:
- Fabrication of realistic kidney phantoms with simulated RCC based on patient CT data.
- Design and 3D printing of a patient-specific surgical guide (3DP-KSG).
- Evaluation of catheter insertion accuracy (point and trajectory) using CT scans of phantoms with the 3DP-KSG.
Main Results:
- The 3DP-KSG demonstrated high accuracy in targeting simulated RCC, with minimal insertion point errors (1.597 ± 0.741 mm).
- Catheter trajectory analysis showed excellent precision with a cosine similarity of 0.990 ± 0.010.
- Insertion point errors along X, Y, and Z axes were 0.611 ± 0.855 mm, 0.028 ± 1.001 mm, and -0.510 ± 0.923 mm, respectively.
- No significant difference in accuracy was observed between operators.
Conclusions:
- The 3DP-KSG provides accurate, quantitative, and immediate intraoperative guidance for RCC localization.
- This technology facilitates precise tumor removal during partial nephrectomy, potentially improving renal function preservation.