Related Experiment Video
Updated: Jul 16, 2025

High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels
Published on: January 27, 2013
The "One-Step" approach for QT analysis increases the sensitivity of nonclinical QTc analysis
Derek J Leishman1, David L Holdsworth2, D Adam Lauver3
1Eli Lilly and Company, Indianapolis, Indiana, USA.
Abstract:
Whether a compound prolongs cardiac repolarization independent of changes in beat rate is a critical question in drug research and development. Current practice is to resolve this in two steps. First, the QT interval is corrected for the influence of rate and then statistical significance is tested. There is renewed interest in improving the sensitivity of nonclinical corrected QT interval (QTc) assessment with modern studies having greater data density than previously utilized. The current analyses examine the effects of moxifloxacin or vehicle on the QT interval in nonhuman primates (NHPs) using a previously described one-step method. The primary end point is the statistical sensitivity of the assessment. Publications suggest that for a four animal crossover (4 × 4) in NHPs the minimal detectable difference (MDD) is greater than or equal to 10 ms, whereas in an eight animal crossover the MDD is ~6.5 ms. Using the one-step method, the MDD for the four animal NHP assessments was 3 ms. In addition, the one-step model accounted for day-to-day differences in the heart rate and QT-rate slope as well as drug-induced changes in these parameters. This method provides an increase in the sensitivity and reduces the number of animals necessary for detecting potential QT change and represents "best practice" in nonclinical QTc assessment in safety pharmacology studies.
Related Concept Videos
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...

