Related Experiment Video
Updated: Jul 16, 2025

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Removal of a flanged ventricular catheter: illustrative case
Background:
Flanged ventricular catheters were created in the 1970s to decrease shunt failure by preventing the holes at the catheter tip from contacting the choroid plexus. However, the flanges on the catheter frequently scarred within and tether to the choroid plexus, resulting in higher rates of intraventricular hemorrhage when removed. Today, flanged catheters are rarely encountered.
Observations:
The authors describe an illustrative case of a 7-year-old girl recently adopted from another country with a history of myelomeningocele and shunted hydrocephalus. She had been treated with a flanged catheter at birth. She presented with a shunt infection, which required removal of the flanged catheter tethered to the choroid.
Lessons:
The authors illustrate the safe removal of a posterior-entry flanged ventricular catheter tethered to the choroid plexus using monopolar flexible electrocautery. The removal was monitored with a flexible endoscope inserted from an ipsilateral anterior burr hole and was followed by an endoscopic third ventriculostomy.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management

