Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic
Yukiko Hikasa1, Satoshi Suzuki2, Shunsuke Tanabe3
1Department of Anesthesia and Intensive Care, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan. yhikasa@ncc.go.jp.
Purpose:
It remains unknown whether stroke volume variation (SVV), pulse pressure variation (PPV), and dynamic arterial elastance (Eadyn) are suitable for monitoring fluid management during thoracoscopic esophagectomy (TE) in the prone position with one-lung ventilation and artificial pneumothorax. Our study aimed to evaluate the accuracy of SVV, PVV, and Eadyn in predicting the fluid responsiveness in these patients.
Methods:
We recruited 24 patients who had undergone TE. Patients with a mean arterial blood pressure ≤ 65 mmHg received a 200-ml bolus of 6% hydroxyethyl starch over 10 min. Fluid responders showed the stroke volume index ≥ 15% 5 min after the fluid bolus. Receiver operating characteristic (ROC) curves were generated and area under the ROC curve (AUROC) was calculated.
Results:
We obtained 61 fluid bolus data points, of which 20 were responders and 41 were non-responders. The median SVV before the fluid bolus in responders was significantly higher than that in non-responders (18% [interquartile range (IQR) 13-21] vs. 12% [IQR 8-15], P = 0.001). Eadyn was significantly lower in responders than in non-responders (0.55 [IQR 0.45-0.78] vs. 0.91 [IQR 0.67-1.00], P < 0.001). There was no difference in the PPV between the groups. The AUROC was 0.76 for SVV (95% confidence interval [CI] 0.62-0.89, P = 0.001), 0.56 for PPV (95% CI 0.41-0.71, P = 0.44), and 0.82 for Eadyn (95% CI 0.69-0.95, P < 0.001).
Conclusions:
SVV and Eadyn are reliable parameters for predicting fluid responsiveness in patients undergoing TE.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...