Introduction:
The risk of unfavourable outcomes after an acute heart failure (AHF) episode remains high. Effective decongestion, reflected by haemoconcentration (HC), may guide therapy. Optimal timing of HC remains unspecified.
Methods:
We analysed the AHF registry to evaluate the prognostic differences of various timing of HC. Subjects were divided into 3 groups by time of reaching HC.
Results:
The groups differed in terms of 1-year occurrence of a composite of the mortality and AHF hospitalization (26% vs. 46% vs. 40%, early vs. late vs. no HC, p = 0.016).
Conclusions:
Patients reaching HC earlier seem to present the best prognosis regarding the analysed composite endpoint.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
05:41Left Anterior Descending Coronary Artery Ligation for Ischemia-Reperfusion Research: Model Improvement via Technical Modifications and Quality Control
Published on: December 16, 2022
Related Concept Videos
Heart Failure V: Medical Management
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Heart Failure II: Pathophysiology
Heart Failure Drugs: β-Blockers
Heart Failure Drugs: Diuretics
Heart Failure VI: Adjunct Therapies