Related Experiment Video
Updated: Aug 16, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Self-Expandable Prosthesis Valve Adaptation: Non-Uniform Expansion and Stent Frame Decoupling
Marco Moscarelli1, Giulia Sollami2, Emanuele Lentini1
1Departments of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care & Research, Palermo, Italy.
Abstract:
The incidence of non-uniform expansion in the context of the self-expandable transcatheter heart valve (THV) is little investigated, along with stent-frame decoupling, which is a form of stent adaptation, in which the lower part of the THV stent conforms to both the ellipticity of the left ventricle outflow tract and the native annulus while maintaining the higher part of the valve more circular. We analyzed post-implant multi-detector computed tomography scans in 50 patients. Prosthesis non-uniform expansion was assessed by computing the prosthesis eccentricity on 6 prespecified levels: (1) frame inflow, (2) native annulus, (3) leaflet inflow, (4) prosthesis waist, (5) leaflet outflow, and (6) frame outflow. Stent-frame decoupling was assessed by comparing the mean eccentricity on 6 different prosthesis levels. Implantation depth, leaflet expansion and alignment, and residual anatomic sinus area ratios were also calculated. Subclinical leaflet thrombosis was defined as hypoattenuated lesion of a meniscal shape. At a 12-month follow-up, non-uniform expansion was consistently detected at each valvular level. Highest eccentricity was measured at the native annulus level (eccentricity: 0.54 ± 0.12), while the lowest index at the frame outflow level (0.23 ± 0.11). Similar results were observed in the subgroup analyses of sizes 23, 26, 29, and 34. Eccentricity significantly decreased from the annulus level to the prosthesis frame outflow (p <0.001). Notably, the incidence of mild-to-severe subclinical leaflet thrombosis was relevant (16%). In conclusion, prosthesis non-uniform expansion and stent frame decoupling frequently occur after self-expandable THV replacement. The clinical and hemodynamic implications remain uncertain.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Ankle Joint
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying a...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Plastic Deformations
Expansion and Contraction in Masonry Walls
To...