Large-view x-ray imaging for medical applications using the world's only vertically polarized synchrotron radiation
Chika Kamezawa1,2, Kazuyuki Hyodo1,2, Chiho Tokunaga3
1Photon Factory, Institute of Materials Structure Science, KEK, Tsukuba, Japan.
Abstract:
Objective.X-ray microangiography provides detailed information on the internal structure and function of a biological subject. Its ability to evaluate the microvasculature of small animals is useful for acquiring basic and clinical medical knowledge. The following three conditions are necessary to attain detailed knowledge of biological functions: (1) high temporal resolution with sufficient x-ray intensity, (2) high spatial resolution, and (3) a wide field of view. Because synchrotron radiation microangiography systems provide high sapatial resolution and high temporal resolution as a result of their high x-ray intensity, such systems have been developed at various synchrotron radiation facilities, starting with the photon factory, leading to numerous medical discoveries. However, the three aforementioned functions are incompatible with the use of synchrotron radiation because the x-ray intensity decreases when a wide field of view is obtained. To overcome these problems, we developed a new x-ray optical system for microangiography in rats using synchrotron radiation x-rays.Approach.Instead of using monochromatic synchrotron radiation x-rays with a conventional double-crystal monochromator, we used white synchrotron radiation x-rays and an asymmetric Si crystal to simultaneously monochromatize the beam and widen the field of view.Main results.The intensity profile and spatial resolution of the x-ray images were then evaluated. The proposed x-ray optics increased the x-ray intensity and beam width by factors of 1.3 and 2.7, respectively, compared with those of conventional monochromatic x-rays. In addition,in vivostudies on microangiography in rats were performed to confirm that the images had sufficient intensity, spatial resolution, and field of view. One of a series of images taken at 50 ms frame-1was shown as an example.Significance.This x-ray optics provides sufficient x-ray intensity, high spatial resolution, and a wide field of view. This technique is expected providing new insights into the evaluation of the vascular system.
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...