IRMSwin-T: A lightweight shifted windows transformer based on inverted residual structure and residual multi-layer

Shanshan Ding1, Renwen Chen1, Hao Liu1

  • 1College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, People's Republic of China.

PubMed

Related Concept Videos

Design of Transmission Shafts01:16

Design of Transmission Shafts

The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by...
338
Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
157
Three-Winding Transformers01:19

Three-Winding Transformers

Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
252
Instrument Transformers01:23

Instrument Transformers

Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
102
Transmission Shafts: Problem Solving01:09

Transmission Shafts: Problem Solving

Designing a solid shaft that transmits power from a motor to a machine tool involves a series of calculations to ensure the shaft can withstand the stresses applied by bending moments and torques. First, calculate the torque exerted on the gear, considering the power transmitted by the shaft and its rotational speed. Following this, compute the tangential forces acting on the gears, which directly relate to the torque and the gear radius.
Next, use bending moment diagrams for the shaft to...
258
Design of Transmission Shafts - Stress Analysis01:15

Design of Transmission Shafts - Stress Analysis

Designing a transmission shaft requires a thorough understanding of the stresses induced by bending moments and torques, especially in systems where power is transferred through gears. These forces create force-couple systems at the centers of the shaft's cross-sections, leading to both transverse and torsional loading. Although shearing stresses from transverse loads are typically smaller than those from torques and are often overlooked, the significant normal stresses from these loads...
393