Related Experiment Video
Updated: Jul 15, 2025

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Assessing aerobic physical efficiency through temple surface temperature measurements during light, heavy exercise,
Agnieszka Danuta Jastrzębska1, Rafał Hebisz2, Paulina Hebisz2
1Department of Physiology and Biochemistry, Wroclaw University of Health and Sport Sciences, 51-612, Wrocław, Poland. agnieszka.jastrzebska@awf.wroc.pl.
Abstract:
The study was conducted to determine thecorrelation between the selected measures of aerobic physical efficiency and changes in the temple surface temperature in response to light and heavy exercise. 25 physically active men aged 19-25 were recruited for the study. They performed a graded exercise test on a cycle ergometer to measure maximum power (Pmax) and a test verifying the value of maximum oxygen uptake (VO2max). Then, two 3-min submaximal efforts with constant-intensity of 2.2 W·kgLBM-1 and 5 W·kgLBM-1, respectively were performed. During the constant-intensity efforts, the temperature of the temple surface was measured. Then, the difference between the temperature of the temple measured at the end of the exercise and the temperature measured at the beginning of the exercise was calculated (ΔT1-2.2, ΔT1-5, respectively). It was shown that ΔT1-2.2 correlated statistically significantly with VO2max (ml·min-1·kg-1) (r = 0.49; p = 0.01) and Pmax (W·kg-1) (r = 0.41, p = 0.04). Moreover, ΔT1-5 correlated statistically significantly with VO2max (l·min-1) (r = - 0.41; p = 0.04). Changes in body surface temperature in response to light exercise positively correlate with measurements of aerobic physical efficiency, such as VO2max and Pmax. When the exercise intensity is high (5 W·kgLBM-1), the correlation between exercise body temperature changes and VO2max becomes negative.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...