Related Experiment Video
Updated: Jul 15, 2025

Evaluation of Colorectal Cancer Risk and Prevalence by Stool DNA Integrity Detection
Published on: June 8, 2020
The Diagnostic Performance of Fecal Immunochemical Tests for Detecting Advanced Neoplasia at Surveillance Colonoscopy
Grace Berwald1, Graeme P Young2, Charles Cock3
1Department of Medicine, College of Medicine and Public Health, Flinders University, Bedford Park, South Australia, Australia.
Background & Aims:
An increasing burden on health care resources has resulted in a backlog of individuals requiring colonoscopy, with delays in surveillance possibly detrimental for individuals at increased risk of colorectal cancer (CRC). This study investigated the use of a 2-sample fecal immunochemical test (FIT) to establish those most likely to have advanced neoplasia (AN) and in need of prioritized surveillance colonoscopy.
Methods:
This was a prospective study conducted in the tertiary care setting. Participants completed a 2-sample FIT (OC-Sensor, Eiken Chemical Company) within 90 days of surveillance colonoscopy. The sensitivity of FIT for detection of AN (CRC or advanced adenoma) in moderate- and high-risk individuals was determined at fecal hemoglobin thresholds between 2 and 80 μg/g feces.
Results:
A total of 766 patients were included (median age, 66.1 years [interquartile range, 58.1-72.9]; 49.9% male), with AN detected in 8.6% (66/766, including 5 CRC). For moderate-risk individuals (with prior history of adenoma or a significant family history of CRC), sensitivity of FIT for AN ranged from 73.5% at 2 μg/g feces, to 10.2% at 80 μg/g feces. For high-risk conditions (confirmed/suspected genetic syndromes or prior CRC), sensitivity of FIT was similar, ranging from 70.6% at the lowest positivity threshold of 2 μg/g feces, to 11.8% at 80 μg/g feces. Independent variables in the whole cohort for association with detection of AN at surveillance colonoscopy were age (odds ratio, 1.03; 95% confidence interval, 1.00-1.06) and FIT hemoglobin result ≥10 μg/g feces (odds ratio, 1.81; 95% confidence interval, 1.04-3.16).
Conclusions:
The use of FIT before surveillance colonoscopy provides clinicians with insights into the risk of AN. This raises the possibility of a method to triage individuals, facilitating the more efficient management of endoscopic resources.
More Related Videos
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...