Cardiac resynchronization therapy in patients with a coronary sinus reducer: a case series
Christian Grebmer1, Matthias Bossard1, Adrian Attinger-Toller1
1Department of Cardiology, Heart Center Lucerne, Luzerner Kantonsspital, Spitalstrasse 16, 6002 Luzern, Switzerland.
Insights
Cardiac resynchronization therapy (CRT) is feasible in patients with a Coronary Sinus Reducer (CSR) system. Lead extraction after CSR implantation is possible but carries risks, necessitating careful consideration of alternatives.
Area of Science:
- Cardiology
- Interventional Cardiology
- Medical Devices
Background:
- Refractory angina can be treated by reducing coronary sinus venous drainage using the Coronary Sinus Reducer (CSR) system.
- Cardiac resynchronization therapy (CRT) is a standard treatment for heart failure with impaired left ventricular function and dyssynchrony.
- Limited data exists on the combined use of CSR and CRT.
Background:
Reducing venous drainage of the coronary sinus is a promising intervention for refractory angina. Coronary Sinus Reducer (CSR) System™ effectively treats patients with refractory angina, possibly by increasing coronary collateral circulation, and leads to an improvement in their symptoms and quality of life. In patients with impaired left ventricular function and electrocardiographic dyssynchrony, cardiac resynchronization therapy (CRT) is an established treatment. However, there is only one published case report of CRT in a patient implanted with a CSR system. We present the first case series of CRT in patients implanted with the CSR system.
Case Summary:
This case series describes three patients. The first case demonstrated that CRT is feasible in patients implanted with a CSR system. The second case is the first report of a left ventricular lead extraction after CSR, and the third case was complicated due to the patient's medical history; however, CSR system implantation was feasible without major complications.
Discussion:
Our results suggest that CRT is feasible in patients implanted with a CSR system, and lead extraction after CSR system implantation is possible. However, lead extraction in cases of severe adhesions around the CSR system and the coronary sinus may be associated with a high risk of complications; alternative options should be discussed at an early stage.
More Related Videos
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy V: Interprofessional Care
Dysrhythmias VI: Management of Dysrhythmias
Cardiomyopathy IV: Restrictive Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Mitral Stenosis III: Medical Management