Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
A randomized control trial to assess optical coherence tomography parameters of the Xlimus drug-eluting stent: the
Luca Testa1, Mattia Squillace1, Nicoletta Ventrella1
1Department of Cardiology, IRCCS Policlinico S. Donato, Milan, Italy.
Background:
Third generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES.
Methods:
A total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6-9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected.
Results:
Most of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (-0, 04-0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (-0, 06-4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints.
Conclusions:
The study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy.
Clinical Trial Registration:
ClinicalTrials.gov, identifier (NCT03745053).
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...