Central Composite Design Expert-Supported RP-HPLC Optimization and Quantitative Evaluation of Efonidipine
Bhoomi D Patel1,2, Hitesh J Vekaria1
1Department of Quality Assurance, School of Pharmacy, RK University, Rajkot-Bhavnagar Highway, Kasturbadham, Rajkot - 360020, Gujarat, India.
Abstract:
Central composite design based RP-HPLC method optimization for the synchronized analysis of Efonidipine Hydrochloride Ethanolate (EFE) and Chlorthalidone (CHL) in tablet. The effective separation was performed using Inertsil ODS C18 column (250 × 4.6 mm, 5 μm), PDA detector with 0.05 M KH2PO4 Buffer (pH 4.5): Acetonitrile (40:60%v/v) mobile phase. Independent variables were investigated include the concentration of KH2PO4 (X1) and flow rate of mobile phase (X2). Based on responses obtained (retention time, resolution and tailing factor), the optimum condition selected was X1 = 40% and X2 = 1 ml/min. Optimized HPLC condition was validated by assessing validation parameters and it meets the acceptance criteria set by ICH. The linear calibration curve was found to be in the quantity range 6.25-18.75 and 20-60 μg/ml Assay of drugs was 100.94 and 100.06% for CHL and EFE. The validated RP-HPLC-PDA method can be used for routine analysis of EFE and CHL in tablet.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Instrumentation
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...